《工程塑料应用》 2021年第06期
DOI:10.3969/j.issn.1001-3539.2021.06.014
基于正交试验的医用微球囊拉伸吹塑优化设计
代光辉,张晴晴,靳国宝
巢湖学院机械工程学院,安徽巢湖 238000 
Optimization Design of Stretch Blow Molding Process of Medical Microballoon based on Orthogonal Test
Dai Guanghui, Zhang Qingqing, Jin Guobao
College of Mechanical Engineering, Chaohu University, Chaohu 238000, China 
摘要:为提高医用微球囊壁厚均匀性以及成型稳定性,以成型温度、成型压力、拉伸距离和保温时间四个拉伸吹塑工艺参数为优化对象,在完成田口正交试验与极值分析的基础上,进一步择优缩小各因素的水平范围,设计并实施了具有因素交互作用的正交试验。交互试验结果表明,成型温度和成型压力的交互作用及成型温度和拉伸距离的交互作用对球囊壁厚均匀性影响明显。依据两次正交试验获得的优化参数进行成型实验与测量统计,对比发现,交互正交试验优化结果下的球囊壁厚均匀性平均值略高于田口正交实验优化结果,达到96.03%,两者之间的差值为0.17%;但是两组参数下球囊壁厚均匀性的方差相差较大,前者相较于后者降低了10.58%,表明交互正交试验优化结果提高了球囊成型的稳定性。 
Abstract:An orthogonal experiment with factor interaction was designed and implemented with the level range of each factor was further narrowed based on the completion of Taguchi orthogonal test and extreme value analysis, taking the four stretch blow molding process parameters of molding temperature, molding pressure, stretching distance, and holding time as optimization objects to improve the uniformity of wall thickness and molding stability of medical microballoons. The interactive test results show that the interaction of molding temperature and molding pressure, as well as molding temperature and stretching distance, have obvious effects on the wall thickness uniformity of the balloon. The molding experiments and measurement statistics were performed based on the optimized parameters obtained from these two orthogonal tests. It can be found from the comparison that the average value of the balloon wall thickness uniformity under the optimization results of the interactive orthogonal experiment is 96.03%, which is slightly higher than that of the Taguchi orthogonal experiment, and the difference between these two experiments is 0.17%; however, the variance of the balloon wall thickness uniformity under the former test is reduced by 10.58% compared with the latter, which shows the great difference between these two tests and indicates that the optimization results of the interactive orthogonal experiment improve the ball stability of ball molding. 
关键词:医用微球囊;拉伸吹塑;工艺优化;正交试验;交互作用 
Keywords:medical microballoon; stretch blow molding; process optimization; orthogonal experiment; interaction 
基金:安徽省高校自然科学研究重大项目(KJ2018ZD045),巢湖学院科学研究重点项目(XLZ-202001),巢湖学院重点实验室项目(kj20zsys03) 
本文引用格式:
代光辉,张晴晴,靳国宝.基于正交试验的医用微球囊拉伸吹塑优化设计[J].工程塑料应用,2021,49(6):78-83.
Dai Guanghui,Zhang Qingqing,Jin Guobao. Optimization design of stretch blow molding process of medical microballoon based on orthogonal test[J]. Engineering Plastics Application,2021,49(6):78-83. 

原文:
 
相似文章:
  基于计算机辅助的聚乳酸3D打印工艺研究
2021年第04期
  ABS汽车仪表盘加工工艺对其质量影响
2020年第12期
  基于灰色关联分析的FDM工艺参数与制件精度关系研究
2020年第11期
  PVC-U管材挤出机头的流道数值模拟及优化
2020年第11期
  基于灰色关联分析法的COC芯片翘曲变形注塑工艺优化
2020年第10期
  基于MPI的雾灯盖板高光成型参数优化
2020年第08期
  帆船绳钩注塑模具设计与工艺优化
2020年第06期
  选择性激光烧结聚苯乙烯蜡模的尺寸精度
2020年第03期
  FDM 3D打印工艺参数对PLA制件力学性能的影响
2020年第01期
  基于重叠CAE分析的蓝牙环双射旋转注塑模具设计
2019年第11期
《工程塑料应用》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878057 85878223 85878148 85878278
鲁ICP备05018524号-5